Products > Integrated Conditioning Acquisition & Control Systems > Integrated Conditioning Acquisition & Control System Accessories  
 

Integrated Conditioning Acquisition & Control System Accessories


Click on a Product to view details.

CDP

Model CDP Control & Data Processor


Features

  • High Performance Local, Remote and/or Distributed Operation
  • Supports up to 64 Series 6000 Enclosures
  • Provides the Highest Stability and Assurance of Data Capture Possible

Description

The Control & Data Processor (CDP) is a Windows based PC that has been customized for high performance and stability. The CDP connects to a single or multiple Series 6000 enclosures and can be configured in a number of ways to fit any application. Operating and test utility software can be installed on the CDP to facilitate local setup, control, recording, display and troubleshooting of the 6000 data acquisition system. Combined with the Series 6000 DAS and the Operators Workstation ...

ACS2000

Model ACS2000 Calibration System


Features

  • Automated NIST traceable calibration of amplifiers and signal conditioning
  • Performance measurement and certification
  • Archived and printed test reports
  • Increased measurement accuracy by periodic recalibration
  • Minimize human errors
  • Cable sets and software available for Series 5800, 6000, 6100, 6700, 7000 and 9000 Pacific product lines

Description

Pacific Instruments Model ACS2000, Automated Calibration System will align, calibrate and certify programmable transducer signal conditioners and instrumentation amplifiers to factory or user performance specifications. Product specific cable sets and software enable a single calibration system ...

6084-32-RTD

Model 6084-32-RTD Uniform Temperature Reference


Description

The Uniform Temperature Reference (UTR) converts from specific thermocouple wire to copper wire within a uniform temperature environment. A single UTR can accommodate up to 32 thermocouples of different types. A precision RTD sensor measures the temperature of the thermocouple wire connection and this measurement is used by software to make cold junction temperature compensation and display temperatures in Celsius, Fahrenheit or Kelvin. PI660 Software provides compensation and look-up table conversion for B, C, E, J, K, N, R, S and T thermocouples. The UTR is a passive device requiring no external power.

The 6084-23-RTD has screw terminals for thermocouple terminations inside the enclosure and accessed by ...

© 2024, Pacific Instruments, Inc. Catalog IndexPrivacy PolicySite Map