Model 6815, Turnkey Voltage/IEPE/Strain/Bridge/LVDT Data Acquisition System
|
|
|
|
Features- 16 or 32 Ch Voltage/ICP/IEPE/Strain/Bridge/LVDT Input
- BNC & RJ45 Input Connectors
- AC/DC Coupling for Voltage/IEPE
- Bridge Completion, Shunt Cal & Balance for Strain/Bridge
- IRIG Time A, B or G
- PI660 Turnkey Software Included
- Shipping Container
DescriptionSeries 6800 for portable applications is a ready-to-run, high performance measurement system that is DC powered for mobile applications. All connections are front mounted for easy installation in tight places or on the go. 6800 systems come equipped with a conditioner, amplifier, filter and digitizer. Each channel has a front mounted connector specific to a measurement type: RJ-45 for 8-wire bridge transducers and BNC for voltage or ICP/IEPE inputs. Individual channels have a differential ±10V input and can digitize and record data to 16-bit resolution with upper and lower programmable alarm capability that is checked each time the output is digitized. Solutions are available for providing digital outputs based on these alarm conditions. Systems interface to a familiar Windows based Operator Workstation over USB where the included software, PI660, is used for setup, display and acquisition of measurement data. PI660 allows for acquisition and control of one or many 6800 systems and provides real time data display. Data can be displayed and recorded in any number of ways, creating a versatile system that can fit any application and can be easily expanded or customized, should test requirements change. Multiple systems can be combined for larger and/or distributed installations, made capable with an onboard, distributed sample clock bus. Programming and data transfer are over USB which provides high data transfer rates with low, predictable latency. It interfaces to the USB port provided on most PC computers, including laptops for ultimate portability. Data Redundancy is optionally available. A 2.5" HD (Model 6095) mounts on the USB controller board in each system and provides a redundant recording point for the DAS. In the unlikely event the Operator’s Workstation or DAS Software fails, data will continue to record and can be recovered from the system post test. The Operator’s Workstation (6800-PCCOWU-LT) is the primary control and data recording point for the Series 6800 DAS. The PCCOWU-LT is typically a laptop, connected to the USB port and runs PI660 Data Acquisition Software for system setup, calibration, display, recording, distribution and export.
|
|
|
|
|
Measurement Type
|
|
4-20mA Bridge ICP/IEPE Insrumentation Amp Position Strain Gage Voltage
|
|
Analog Bandwidth
|
|
100 kHz
|
|
Excitation/Transducer Power
|
|
+/-12V +/-15V 24V ICP
|
|
Filter
|
|
4-Pole
6-Pole
8-Pole
|
|
Sample Rate
|
|
Up to 200 kS/s
|
|
|
|
|
Configuration
|
|
8 channels, 2 to 8 wire with guard shield. Bridge config is programmable for 1/4, 1/2 and full bridge. 350 Ohm completion resistor standard, alternate value may be specified.
Differential, 2-wire with shield.
|
|
Input Type
|
|
Programmable AC or DC input. Input attenuator and current input are available.
|
|
Range
|
|
±2 mV to ±10 Volts.
|
|
Impedance (AC)
|
|
100k Ohms, shunted by 1,000 pF.
|
|
Impedance (DC)
|
|
50 Megohms, shunted by 500 pF.
|
|
Protection
|
|
±50 Volts differential and common mode.
|
|
Balance
|
|
Automatic by program control. Balance accuracy ±0.05% of range, ±1 mV RTO. Stability ±0.02% for 8 hours, ±0.005 %/ºC. Range provided is 3.5 mV/V for 350 Ohm bridge.
|
|
Impedance
|
|
50 Megohms, shunted by 500 pF.
|
|
|
|
|
|
|
Gain
|
|
Programmable 1 to 5000, in 1, 2, 3, 5 steps, with ±0.05% accuracy
|
|
Gain Stability
|
|
±0.01%, ±0.005%/ºC.
|
|
Linearity (Amplifier)
|
|
±0.01% for Gains < 1,000, ±0.02% for gains > 1,000.
|
|
Common Mode
|
|
60 dB plus gain in dB to 110 dB, DC to 60 Hz.
|
|
CM Voltage
|
|
±10 V
|
|
Zero
|
|
Automatic to ±1 mV.
|
|
Zero Stability X1
|
|
±1 mV, ±0.2 mV/ºC
|
|
Zero Stability X1000
|
|
±5 mV, ±1 mV/ºC
|
|
Noise X1
|
|
0.2 mV RMS for 20 kHz bandwidth.
|
|
Noise X1000
|
|
2.8 mV RMS for 20 kHz bandwidth.
|
|
Bandwidth
|
|
DC to 100 kHz (-3 dB). 1 Hz to 100 kHz (-3 dB) in AC coupled mode.
|
|
Slew Rate
|
|
3.2 V/µS
|
|
Analog Output (Amplifier)
|
|
±10 Volts full scale, 20 mA. Programmable for wideband or filtered response. Buffered Analog Output.
|
|
|
|
|
|
|
|
|
Voltage Substitution
|
|
Alternate input for external calibration source. Programmable 1, 0.1 and 0.01, attenuation with ±0.02% accuracy. Attenuator output may be connected to output bus for accuracy check.
|
|
Zero Calibration
|
|
Amplifier input disconnected and shorted for zero calibration.
|
|
|
|
|
Protocol
|
|
Control and data interface is USB 2.0
|
|
Software
|
|
Window's driver (Both 32 and 64-bit) provides high-level operating command set. Fully compatible with all implementations of PI660 operating software
|
|
Control Inputs
|
|
TTL inputs for Start, Stop and Trigger assert flags in the header of output data that initiate software control operations
|
|
Alarms
|
|
Warning and alarm buses may be independent or shared between enclosures and may initiate an output from a digital I/O type module. Two alarms each with upper and lower limits that are programmable from negative to positive full scale. Limits checked on each ADC sample.
|
|
|
|
|
|
|
|
|
Calibration
|
|
15-Pin Type D mounted on rear panel. Mating connector supplied.
|
|
Control
|
|
15-Pin Type D mounted on rear panel. Mating connector supplied.
|
|
Synchronization
|
|
Sampling clock synchronization for multiple rack systems. RJ45 connector on controller board. Category 5, 2-meter cable supplied.
|
|
USB
|
|
2-meter cable supplied.
|
|
|
|
|
|
|
|
|
Ordering Information
|
|
6815-16 - 16-Ch 12VDC Portable DAS, 8 Voltage/IEPE BNC & 8 Strain/Bridge/LVDT RJ45
6815-32 - 32-Ch 12VDC Portable DAS, 16 Voltage/IEPE BNC & 16 Strain/Bridge/LVDT RJ45
|
|
Accessories
|
|
6800-PCCOWU-LT - Operator’s Workstation, Laptop
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|