Pacific Instruments, Inc. Pacific Instruments, Inc.
4080 Pike Lane
Concord, CA 94520
www.pacificinstruments.com

(925) 827-9010
salesrequest@pacificinstruments.com
Products > Integrated Conditioning Acquisition & Control Systems > Integrated Conditioning Acquisition & Control System Accessories > Model ACS2000  


Model ACS2000, Calibration System


Features

  • Automated NIST traceable calibration of amplifiers and signal conditioning
  • Performance measurement and certification
  • Archived and printed test reports
  • Increased measurement accuracy by periodic recalibration
  • Minimize human errors
  • Cable sets and software available for Series 5800, 6000, 6100, 6700, 7000 and 9000 Pacific product lines

Description

Pacific Instruments Model ACS2000, Automated Calibration System will align, calibrate and certify programmable transducer signal conditioners and instrumentation amplifiers to factory or user performance specifications. Product specific cable sets and software enable a single calibration system to be used with any supported Pacific Instrument's products.

The ACS2000 is a fully automated test station with the flexibility to run a single performance test or complete calibration and certification procedures. It provides uniform performance testing regardless of operator ability level. Automated calibration and certification increases productivity by reducing the time to calibrate a unit by as much as 80%, providing a quick payback of the initial investment. It also eliminates human errors that may occur when setting up instrument parameters and measuring and recording test results.

The system operates with a Windows-based PC computer, running test and calibration programs in a graphical user interface. Standard calibration and certification procedures are controlled by ASCII text files which are easily modified to change test parameters and limits using a word processing program or text editor. Measured performance data is archived by unit serial number in HTML format. A print utility generates hard copy test reports.

The automated test system consist of Pacific’s isolated and shielded input-output test fixture, signal switching matrix, AC/DC voltmeter, precision DC voltage standard, function generator, oscilloscope and computer all mounted in a cabinet with large casters Software and cable set are included for one product. Software and cables for other product types may be purchased seperately.







Specifications  · Ordering Information 

Specifications

Certification Procedures

Balance
Bandwidth

Common Mode Rejection

Excitation Current and Limit

Excitation Noise

Excitation Regulation

Excitation Voltage and Limit

Filter Response, Low and High Pass

Front Panel Test Jacks

Gain

Input Impedance

Linearity

Multiple Outputs Gain and Zero

Noise

Resistance Shunt Calibration

Resistance Substitution Calibration

Source Current

Voltage Calibration Accuracy

Zero

Calibration Procedures

ADC Gain and Zero
Current Excitation Levels

Gains

Modify Calibration Date and Information

Monitor Accuracy and Zero

Voltage Excitation Levels


Ordering Information 

Ordering Information

ACS2000 - Calibration System

Pacific Instruments, Inc. · 4080 Pike Lane · Concord, CA 94520 · www.pacificinstruments.com