Pacific Instruments, Inc. Pacific Instruments, Inc.
4080 Pike Lane
Concord, CA 94520
www.pacificinstruments.com

(925) 827-9010
salesrequest@pacificinstruments.com
Products > Integrated Conditioning Acquisition & Control Systems > Integrated Conditioning Acquisition & Control System I/O Modules > 6000 Series Analog I/O Modules > Model 6030  


Model 6030, 2-Channel Strain/Bridge/IEPE Amplifier-Filter-Digitizer


Features

  • Dual inputs, strain/bridge or IEPE transducers
  • Programmable bridge configuration
  • Voltage & current excitation with remote sensing per channel
  • Automatic zero & balance
  • Voltage substitution and two or four step shunt calibration
  • Gains 1 to 5,000 up to 100 kHz bandwidth with 0.05% accuracy
  • Programmable low-pass filters
  • Up to 200kS/s per channel with 16-bit resolution
  • Dual buffered 10 Volt analog outputs

Description

Model 6030 is a two-channel, fully automated, high bandwidth, signal conditioning amplifier, filter and digitizer with dual inputs. The bridge input has voltage and current excitation, automatic balance, shunt calibration and programmable configuration for 1/4, 1/2 and full bridge transducers. The AC-coupled auxiliary input is for ICP/IEPE, dynamic strain and other voltage output transducers.

The 6030 employs an amplifier/digitizer-per-channel architecture, which provides high bandwidth and digitizing speed with excellent channel-to-channel time correlation. It offers the highest accuracy and completely eliminates crosstalk between channels. Using Pacific's PI660 software zero and gain calibration and correction are automatic.

The bridge inputs have programmable constant voltage and constant current excitation, automatic balance and a shielded 8-wire input that supports remote sensing, shunt calibration and programmable bridge completion for 120 and 350 Ohm gages. Strain gages other than 120 or 350 Ohms are accommodated by changing a completion resistor. A two-wire auxiliary input for ICP type transducers has 1-20 mA constant current excitation with AC signal coupling.

Two-step local and remote shunt calibration is standard. Four-step remote shunt with plug-in resistor card is optional. Voltage substitution is provided for gain calibration with programmable attenuation, which makes the distribution of calibration signals less susceptible to contamination by noise and offsets. The programmable attenuator has steps of 1, 0.1 and 0.01 with 0.02% accuracy and a post-attenuator output is available for verification and calibration.

The differential instrumentation amplifier has programmable gains from 1 to 5,000 and automatic zero. Zero and gain calibration and correction are automatic using Pacific's PI660 software. Bandwidth is up to 100 kHz. The amplifier is followed by a low-pass filer that reduces alias errors in the sampled data. A high speed analog-to-digital converter digitizes the amplified and filtered signal for output to the 6000 data bus. In addition, each channel has a ±10 Volt calibrated analog output and a ±10 Volt monitor output.

The standard filter is a programmable four-frequency, eight-pole Bessel low-pass. A programmable, four-pole Bessel, low-pass filter with 1 Hz or 5 Hz frequency resolution is optional. Either the standard or optional filters may be obtained with Butterworth or other response characteristic.







Overview  · Input  · Bridge Input  · Excitation/Transducer Power  · Amplifier  · Filter  · Digitizer  · Calibration  · Mechanical  · Specifications  · IEPE Input  · Voltage Excitation / Transducer Power  · Current Excitation / Transducer Power  · Ordering Information 

Overview

Measurement Type

Bridge
ICP/IEPE

Strain Gage

Analog Bandwidth

50 kHz
100
kHz

Excitation/Transducer Power

Current
ICP

Voltage

Filter

8-Pole

Sample Rate (Digitizer)

Up to 200 kS/s

Analog Output

Buffered Analog Output


Input

Configuration

Dual input for Bridge or ICP/IEPE transducers with digitized and analog outputs


Bridge Input

Bridge Configuration

2 channels, 2 to 8 wire inputs, input (2), excitation (2), excitation sense (2) and shunt calibration (2) with shield. Programmable bridge completion for half bridges and 120 Ohm and 350 Ohm quarter bridges. Other gage resistances by request.

Bridge Balance

Automatic by program control. Balance accuracy ±0.05% of range, ±1 mV RTO.

Bridge Stability

±0.02% for 8 hours, ±0.005%/°C. Range set by resistor up to 25 mV/V, 2.5 mV/V (350 Ohms) installed.

Input Impedance (Bridge Input)

50 Megohms, shunted by 500 pF.

Input Protection (Bridge Input)

±50 Volts differential, ±30 Volts common mode without damage.

Configuration (IEPE Input)

AC-coupled, 2-wire with shield. High-pass <1 Hz.

ICP Transducer

Current source 1 to 20 mA, 6 mA supplied.

Input Impedance (IEPE Input)

100K Ohms

Input Protection (IEPE Input)

±50 Volts without damage.


Excitation/Transducer Power

Voltage (Constant Voltage)

Programmable from 0.1 to 10.24 Volts with 2.5 mV resolution. Calibrated 1-Volt steps ±0.1%.

Current (Constant Voltage)

50 mA limited to 70 mA maximum.

Regulation (Constant Voltage)

Each channel individually regulated. ±0.01% over input voltage range and no-load to full load.

Stability (Constant Voltage)

±0.01% for 30 days. Temperature coefficient less than ±0.005 %/ºC.

Noise (Constant Voltage)

200 µV peak-to-peak, DC to 10 kHz

Monitor (Constant Voltage)

Excitation voltage or current is read by a program instruction. Accuracy is ±0.2%.

Output Range (Constant Current)

Programmable 0.1 mA to 51.2 mA with 12.5 µA resolution. Calibrated 5 mA steps ±0.1%.

Compliance (Constant Current)

0.1 to 10 V

Regulation (Constant Current)

±0.01% or ±0.1 µA for 10% line change.

Noise (Constant Current)

2 µA or 5 µV peak-to-peak DC to 10 kHz.

Stability (Constant Current)

±0.01% or ±2 µA for 30 days. Temperature coefficient is less than ±0.005% or ±1 µA/ºC.

Monitor (Constant Current)

Excitation voltage or current is read by a program instruction. Accuracy is ±0.2%.


Amplifier

Range

±2 mV to ±10 Volts.

Gain

Programmable 1 to 5000, in 1, 2, 3, 5 steps, with ±0.05% accuracy.

Gain Stability

±0.02% for 30 days, ±0.005%/ºC.

Linearity (Amplifier)

±0.01% for gains < 1,000, ±0.02% for gains 1,000 and above.

Common Mode

60 dB plus gain in dB to 120 dB for balanced input and 110 dB for a 350 Ohm source unbalanced, DC to 60Hz.

CM Voltage

±10 Volts

Zero (Amplifier)

Automatic zero to 12 5V RTI or 11.0 mV RTO whichever is greater.

Zero Stability

±5 µV RTI, ±1 mV RTO at constant temperature, ±1 µV RTI/ºC, ±0.2 mV RTO/ºC. Short term: ±2 µV RTI, ±0.4 mV RTO for 8 hours.

Source Current

±5 nA, ±0.05 nA/ºC

Noise (10 kHz)

2.0 5V RTI plus 0.3 mV RTO, RMS.

Bandwidth

6030 - 50 kHz (-3 dB) for gains to 1,000, 20 kHz for gains above 1,000
6030HF - 100 kHz (-3 dB) for gains to 1,000, 50 kHz for gains above 1,000

Slew Rate

5 V/µS

Gain Linearity

±0.01% for gains < 1,000, ±0.02% for gains 1,000 and above.

Input Impedance

50 Megohms, shunted by 500 pF.

Input Protection

150 Volts differential, 130 Volts common mode without damage.

Overload Recovery

Recovery time is 120 µS to within ±0.1% for a 10 times overload to ±10 Volts.


Filter

Type (Standard Filter)

6030 4-Frequency 8-pole, low-pass Bessel, 150Hz, 525Hz, 2.5kHz, 10kHz.
6030HF 4-Frequency 8-pole, low-pass Bessel, 300Hz, 1.25kHz, 5kHz, 20kHz.

Type (Optional Programmable Filter)

6030-PF10/20K Continuously programmable 4-pole, low-pass Bessel, 10 Hz to 20 kHz.
6030-PF4/10K Continuously programmable 4-pole, low-pass Bessel, 4 Hz to 10 kHz.

Other

Other filter characteristics and cut offs available.

Standard Filter

6030: 4-Frequency 8,Pole Bessel. 150 Hz, 625 Hz, 2.5 kHz, 10 kHz and wideband.
6030HF: 4-Frequency 8, Pole Bessel. 300 Hz, 1.25 kHz, 5 kHz, 20 kHz and wideband.

Programmable Filter

6030: 4-Pole Bessel, continuously programmable from 4 Hz to 1 kHz, 1 Hz resolution, 12% accuracy. 1 kHz to 10 kHz, 5 Hz resolution, 15% accuracy.
6030HF: 4-Pole Bessel, continuously programmable from 10Hz to 20kHz, 5 Hz resolution, 15% accuracy.


Digitizer

Sample

±50 nS time correlation channel-to-channel.

Resolution

16-bits, two's complement output.

Digitizer Linearity

±1½ LSB (±0.004%)

Continuity

Monotonic to 15 bits.

Alarms

Two alarms each with upper and lower limits that are programmable from negative to positive full scale. Limits checked on each ADC sample.

Rate

6030: Programmable up to 100 kS/s digitizer per channel.
6030HF: Programmable up to 200 kS/s digitizer per channel.


Calibration

Shunt (Standard)

Two steps, single shunt. Calibration resistors mount in bifurcated terminals. Program selection of internal or external shunt connection.

Shunt (Optional)

Four-step, single, external shunt. Calibration resistors mounted on a plug-in card. May be wired for local shunt at the input connector.

Shunt Resistors

Installed shunt resistors provide 0.502 and 0.250, ±0.1% mV/V for 350 Ohm bridge. Customer specified and 0.01% shunt resistors are available.

Voltage (Calibration)

Alternate input for external calibration source. Programmable 1, 0.1 and 0.01, attenuation with ±0.01% accuracy. Attenuator output may be connected to bus for external monitoring.

Zero Calibration

Amplifier input disconnected and shorted for zero calibration.

Voltage Substitution

Alternate input for external calibration source. Programmable 1, 0.1 and 0.01, attenuation with 10.01% accuracy. Attenuator output may be connected to bus for external monitoring.

Shunt Calibration

Standard: Two steps, single shunt. Calibration resistors mount in bifurcated terminals. Program selection of internal or external shunt connection.

Optional: Four-step, single, external shunt. Calibration resistors mounted on a plug-in card. May be wired for local shunt at the input connector.

Resistors: Installed shunt resistors provide 0.502 and 0.250, 10.1 % mV/V for 350 Ohm bridge. Customer specified and 0.01% shunt resistors are available.


Mechanical

Mounting

Occupies one slot in Series 6000 enclosures.

Connectors

Input connectors are 15-pin Type D. Outputs are a 9-pin Type D. Type D mates supplied.

Operating Temperature

0 to +50 ºC

Temperature

0 ºC to +50 ºC operating.


Specifications

Sample Rate

Up to 100 kS/s
Up to 200
kS/s


IEPE Input

IEPE Configuration

AC-coupled, 2-wire with shield. High-pass < 1 Hz.

IEPE Excitation

Current source 1 to 20 mA, 6 mA supplied

IEPE Input Protection

150 Volts without damage

IEPE Input Impedance

100K Ohms


Voltage Excitation / Transducer Power

Voltage Excitation

Programmable from 0.1 to 10.24 Volts with 2.5mV resolution.
Calibrated 1-Volt steps ±0.1%. 50 mA limited to 70 mA maximum.

Voltage Excitation Regulation

Each channel individually regulated.
10.01% over input voltage range and no-load to full load.

Voltage Excitation Stability

±0.01% for 30 days. Temperature coefficient less than ±0.005%/ºC.

Voltage Excitation Noise

200 5V peak-to-peak, DC to 10 kHz

Voltage Monitor

Excitation voltage or current is read by a program instruction. Accuracy is 10.2%.


Current Excitation / Transducer Power

Current Excitation

Programmable 0.1mA to 51.2 mA with 12.5 5A resolution. Calibrated 5 mA steps 10.1%.

Minimum Compliance

0.1 to 10 Volts

Current Regulation

±0.01% or ±0.1 µA for 10% line change.

Current Excitation Noise

25A or 55V peak-to-peak DC to 10 kHz.

Current Stability

±0.01% or 125A for 30 days. Temperature coefficient is less than ±0.005% or 115A/0C.

Current Monitor

Excitation voltage or current is read by a program instruction.
Accuracy is 10.2%.


Ordering Information 

Ordering Information

6030-PF4-BE8 - 2-Ch Strain-Bridge-IEPE, 4-Freq, 8-Pole Bessel
6030-PF4/10K-BE4 - 2-Ch Strain-Bridge-IEPE, 4-Pole PF 4Hz-10kHz Bessel
6030HF-PF4-BE8 - 2-Ch Strain-Bridge-IEPE, 4-Freq, 8-Pole Bessel
6030HF-PF10/20K-BE4 - 2-Ch Strain-Bridge-IEPE, 4-Pole PF 10Hz- 20kHz Bessel
6030-S4 - 4-Step Shunt Cal Plug-In Resistor Card (no Resistors).

Pacific Instruments, Inc. · 4080 Pike Lane · Concord, CA 94520 · www.pacificinstruments.com