Pacific Instruments, Inc. Pacific Instruments, Inc.
4080 Pike Lane
Concord, CA 94520
www.pacificinstruments.com

(925) 827-9010
salesrequest@pacificinstruments.com
Products > Integrated Conditioning Acquisition & Control Systems > Integrated Conditioning Acquisition & Control System I/O Modules > 6000 Series Analog I/O Modules > Model 6033  


Model 6033, 8-Channel Strain/Bridge Transducer Amplifier-Filter-Digitizer


Features

  • Quarter, half & full bridge conditioning
  • Voltage excitation up to 12 Volts
  • Shunt & voltage calibration
  • Automatic zero & balance
  • Gains 1 to 5,000 with 0.05% accuracy
  • Four-pole low-pass filter
  • Up to 10 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

Model 6033 may not be regularly available. Please see Model 6035, 6038 or 6039 for similar applications.

The 6033 input module has eight channels of transducer signal conditioning and digitizer. Each channel has regulated voltage excitation, programmable gain instrumentation amplifier, four-pole low pass filter and sample and hold amplifier. The high level outputs are multiplexed and digitized to 16 bits then output to the 6000 data bus. In addition to the digitized output, each channel has a wideband analog output.

The 6033 is used with 1/4, 1/2 and full bridge transducers, potentiometers and low-level voltage signals. It is particularly suited to strain gages where remote sensing is not a requirement. A shielded four-wire input provides signal and excitation connections to the transducer. Excitation is programmable from 0 to 12 Volts for all channels on the module. An individual regulator for each channel prevents loading or a short on one channel from affecting other channels. A calibration mode is provided that measures excitation voltage or current.

Voltage substitution is provided for gain calibration using an external voltage standard. A calibration attenuator enables the voltage standard to be used on its highest accuracy ranges and has a post-attenuator output for verification and calibration. Resistive shunt is provided for transducer calibration. Two alarm with programmable upper and lower limits are provided and checked each time the output is digitized. Analog outputs provide a means to independently monitor or record each channel.







Overview  · Input  · Excitation/Transducer Power  · Amplifier  · Filter  · Digitizer  · Calibration  · Mechanical  · Ordering Information 

Overview

Measurement Type

Bridge
Strain Gage

Analog Bandwidth

1 kHz

Excitation/Transducer Power

Voltage

Filter

4-Pole

Sample Rate (Digitizer)

Up to 10 kS/s

Analog Output

Monitor Output


Input

Configuration

8 channels, 2 to 4 wires plus shield for bridge and voltage. Input configured by plug-in jumpers.

Balance

Automatic by program control. Balance accuracy ±0.05% of range, ±1 mV RTO. Stability ±0.02% for 8 hours, ±0.005 %/ºC. Range set by resistor up to 10 mV/V, 2 mV/V (350 Ohms) is installed.

Impedance

50 Megohms, shunted by 1,000 pF.

Protection

±50 Volts differential, ±30 Volts common mode.


Excitation/Transducer Power

Voltage Excitation

Programmable for 8 channels from 0 to 12 Volts with 3.3 mV resolution. Calibrated 1 Volt ±0.1% steps.

Current

50 mA, limited to 70 mA. Short on one channel will not affect other channels.

Regulation

±0.2% line and no-load to full-load measured at the input connector.

Stability

±0.01%, ±0.005 %/ºC

Excitation Noise

200 µV peak-to-peak.

Monitor

Voltage or current selected by jumper plug.


Amplifier

Gain

Programmable from 1 to 5,000 in 1, 2, 3, 5 steps with ±0.05% accuracy.

Gain Stability

±0.01%, ±0.004%/ºC.

Linearity (Amplifier)

±0.01% for gains < 1,000, ±0.02% for gains 1,000 and higher.

Common Mode

60 dB plus gain in dB up to 106 dB, DC to 60 Hz for ±10 Volts.

Zero (Amplifier)

Automatic to ±1 µV RTI, ±0.5 mV RTO.

Zero Stability

±5 µV RTI, ±1 mV RTO, ±1 µV/ºC RTI,
±0.2 mV/ºC RTO. Short term: ±2 µV RTI,
±0.4 mV RTO for 8 hours.

Source Current

±2 nA, ±0.01 nA/ºC

Noise (10 Hz)

0.5 µV peak, RTI.

Noise (1 kHz)

1.5 µV peak, RTI

Bandwidth

1 kHz
-3
dB

Recovery

800 µS to ±0.1% for 10X overload to ±10 V.


Filter

Type

Four-pole, low-pass Butterworth.

Frequency

Plug-in, 4 Hz to 1 kHz, 10 Hz supplied.

Noise

2 mV peak RTO.

Other

Other filter characteristics and cut offs are available.


Digitizer

Sample

Simultaneous, within ±50 nS channel-to-channel. Droop is less than ±0.005%.

Resolution

16-bits, two's complement output.

Sample Rate

Up to 10 kS/s per channel
Up to 10
kS/s

Digitizer Linearity

2 LSB (0.006%)

Continuity

Monotonic to 15 bits.

Alarms

Two alarms each with upper and lower limits that are programmable from negative to positive full scale. Limits checked on each ADC sample.


Calibration

Shunt

Programmable single shunt, 0.502 mV/V (350 Ohm bridge), ±1% installed.

Voltage Substitution

Alternate amplifier input for external voltage standard. Programmable attenuator steps of 1, 0.1 and 0.01 with ±0.02% accuracy. Output of the attenuator provided on rear panel connector for calibration.

Zero Calibration

Amplifier input disconnected and shorted.


Mechanical

Mounting

Occupies one slot in Series 6000 enclosures.

Connectors

Input connectors are 50-pin Type D. Mates are supplied

Operating Temperature

0 to +50 ºC


Ordering Information 

Ordering Information

6033 - 8-Ch Strain-Bridge, 4-Wire Input.
6081 - Screw Terminal Adapter.

6082 - RJ45 Plug Adapter with Bridge Completion for 120, 350 and 1,000 Ohm Gages.

Pacific Instruments, Inc. · 4080 Pike Lane · Concord, CA 94520 · www.pacificinstruments.com