Model 7200, Ruggedized 16-Channel Strain/Bridge/Voltage Data Acquisition


Features

  • 16-Channels strain gage, bridge or voltage transducers
  • Ethernet control and data interface
  • Real time temperature correction of Gain, Zero & Excitation from -20°C to +50°C
  • 0.05% or better accuracy over full gain & temperature range
  • 10 kHz analog bandwidth, gain 1 to 1,000
  • 24-Bit A/D programmable up to 24k S/s per channel
  • Wide range programmable filter, 80 dB/octave
  • IRIG A, B & G time decoding and recording
  • 1 μS synchronized sampling of multiple enclosures
  • Ruggedized for tough environments
  • 20 to 30 Volt DC power

Description

Pacific’s Ruggedized Series 7200 brings a brand new look to strain gage and transducer data acquisition. A network appliance, each module conditions, amplifies and digitizes the outputs of up to sixteen strain gage, bridge or voltage transducers. The rugged enclosure is designed for installation in wind tunnels, engine test stands and other facilities where it is desired to locate the DAS close to the test article, ultimately reducing installation and cable costs as well as improving signal quality and reliability.

Fully self-contained, the 7200 provides transducer excitation, bridge completion and balance. The transducer output is amplified, filtered to remove signal components that could produce alias errors and digitized to 24-bit resolution. The digitized transducer output is digitally processed providing multiple sample rates, an 80 dB/octave FIR filter and 32-bit floating point output format in millivolts referred to input, millivolts referred to output or user defined engineering units.

Four models are available that differ in their excitation and signal conditioning capabilities. Model 7214A and 7216A for strain gage and bridge transducers have programmable voltage excitation, bridge completion for 120 and 350 Ohm strain gages, shunt calibration and automatic balance. Model 7220A is similar but provides regulated power for transducers with internal electronics. Model 7218A is for voltage inputs. The amplified transducer signals are digitized, processed and output at 10 to 24,000 samples per second, as selected for individual channels. A digital signal processor (DSP) provides low-pass filtering selectable from 10 Hz to 3,000 Hz with 80 db/octave roll-off.

Each module has a 1 Gigabit Ethernet interface for control and data output, which simplifies system wiring and provides remote and distributed operation. IRIG time may be employed to synchronize sampling on multiple modules within 10 microseconds, or a TTL timing may be used to achieve better than 1 microsecond time alignment. Multiple modules with up to 4,096 channels may be connected on a single Ethernet LAN.

The module enclosure features interchangeable end plates that provide fully sealed, ambient air or forced air cooling. Forced air cooling provides the capability to operate over a wide temperature range according to application requirements. Occupying less than 500 cubic inches and weighing less than 14 pounds, the 7200 modules can be installed in locations previously not suitable for data acquisition systems. The Ethernet interface and IRIG timing make it easy to distribute Bricks throughout the test facility, minimizing sensor cabling and installation costs.

The 7200 does not sacrifice performance for size or portability; it features higher accuracy than most systems designed for a laboratory environment. For the 7216, accuracy is better than 0.025% for gains up to 200 and 0.05% for gains above 200 over the temperature range -20°C to +50°C, which can be extended to higher temperatures by forced air cooling.

Series 7200 is supported by Pacific’s PI770 software that provides a ready-to-run application and an SDK for user program development. Calibration and performance verification is accomplished by PANEL72 Maintenance and Calibration software. The ACS2000 Automatic Calibration System automates performance verification and periodic instrument calibration.







Input  · Excitation/Transducer Power  · Amplifier  · Filter  · Digitizer  · Time Synchronization  · Accuracy  · Calibration  · Interface / Communications  · Mechanical  · Ordering Information 

Input

Configuration

7220A: Four-wire input, signal input (2), transducer power (2) and shield.
7214A & 7216A: Six-wire input, signal input (2), excitation (2), excitation sense (2) and shield. Programmable bridge completion for half bridges and 120 Ohm and 350 Ohm quarter bridges.

7220A: Four-wire input, signal input (2), transducer power (2) and shield.

Input Stability

±0.02% for 8 hours, ±0.005%/ºC.

Input Impedance

50 Megohms shunted by 500 pF.

Input Protection

±50 Volts differential, ±50 Volts common mode without damage.

Bridge Balance

7216A: Automatic by program control. Balance accuracy ±0.025% of range, ±1 mV RTO. Range set by resistor up to 25 mV/V, 2.5 mV/V (350 Ohms) installed.


Excitation/Transducer Power

Voltage Excitation

7214A & 7216A: Constant voltage with remote sensing. Programmable from 1 to 15 Volts with 1 mV resolution. Calibrated 1-Volt steps ±0.025% full scale. 50 mA limited to 70 mA maximum.

Voltage Excitation Regulation

±0.1% over input voltage range and no-load to full load.

Voltage Excitation Stability

±0.01%, 0.001%/°C

Voltage Excitation Noise

200 µV peak-to-peak, DC to 10 kHz

Transducer Power

7220A: Regulated voltage. Programmable from 1 to 15 Volts in 1V steps. Regulation and stability ±1%


Amplifier

Input Range

±10 mV to ±10 Volts.

Gain

Programmable from 1 to 1,000 with 0.02% resolution. Thirteen calibrated gain steps are provided: 1, 2, 3, 5, 10, 20, 30, 50, 100, 200, 300, 500, 1000 with ±0.02% accuracy.

Gain Stability

±0.01% for 30 days, ±0.001%/ºC compensated.
±0.05% for 30 days, ±0.005%/ºC without compensation.

Gain Linearity

±0.02 %

Common Mode

60 dB plus gain in dB to 110 dB, DC to 60 Hz.

Operating CM Voltage

±10 V

Zero (Amplifier)

Automatic zero to ±2 µV RTI or ±1.0 mV RTO whichever is greater.

Zero Stability

±2 µV RTI plus ±1 mV RTO over the full temperature range.

Source Current

±40 nA, ±0.4 nA/°C

Noise (10 Hz)

2.0 µV RTI plus 0.3 mV RTO, RMS.

Bandwidth

10 kHz (-3dB)

Overload

Recovery time is 120 µS to within ±0.1% for a 10 times overload to ±10 Volts.


Filter

Type

Finite Impulse Response (FIR) with 128 coefficients.

Frequency

Programmable from 10 Hz to 3 kHz with 80 dB/octave attenuation above cut-off.


Digitizer

Resolution

24-bits, Sigma-Delta type.

Rate

24K samples per second per channel. Individual channels may be programmed to output data at rates from 10 Hz to 24 kHz. Supports all sixteen channels at the highest sample rate.


Time Synchronization

Source

External TTL input or IRIG A, B or G. IRIG G output provided from each 7200 for multiple module synchronization.

Time Alignment

1 µS using external TTL and 10 µS using IRIG channel to channel and module to module.

Output

Days, Hours, Minutes, Seconds, Microseconds may be output at selected positions in the data stream.


Accuracy

7214 Accuracy

The system maintains ±0.05% full scale (2-sigma) uncertainty for gains up to 200 and ±0.1% full scale (2-sigma) uncertainty for gains above 200 over the operating temperature range.

7216 Accuracy

The system maintains ±0.025% full scale (2-sigma) uncertainty for gains up to 200 and ±0.05% full scale (2-sigma) uncertainty for gains above 200 over the operating temperature range.

7218 Accuracy

The system maintains ±0.05% full scale (2-sigma) uncertainty for gains up to 200 and ±0.1% full scale (2-sigma) uncertainty for gains above 200 over the operating temperature range.

7220 Accuracy

The system maintains ±0.05% full scale (2-sigma) uncertainty for gains up to 200 and ±0.1% full scale (2-sigma) uncertainty for gains above 200 over the operating temperature range.


Calibration

Shunt

Two steps of single shunt.

Shunt Resistors

Installed shunt resistors provide 0.502 mV/V and 0.250 mV/V, ±1% for 350 Ohm bridge.

Voltage (Calibration)

The output of a temperature stable, 5-Volt internal reference with ±0.01% stability, X1.0, X0.1 and X0.01 ±0.05% attenuator and 0.0015% resolution on each attenuator setting may be applied to each channel. Accuracy is ±0.2% for gains to and including 100 and ±0.3% for gains over 100. Stability is ±0.01%. Output of the internal reference can be measured on an external connector.

Zero Calibration

Amplifier input disconnected and shorted for zero calibration.


Interface / Communications

Interface

1 Gigabit Ethernet, TCP/IP, control and data.

Data Format

Floating point, 32-bits. Output available in engineering units, Volts or millivolts.

Operation

Supported by PI770 and PANEL72 software.


Mechanical

Connectors

MIL, 1/4-turn locking

Temperature

-20°C to +50°C operating in ambient air. -20°C to +40°C operating fully sealed. Extended temperature range with forced air cooling.

Shock/Vibration

50 Gs, 11 mS all axis. MIL-STD-810F, Catagory 24.

Moisture

NEMA 13

Power (Mechanical)

20 to 30 VDC, 3A

Width

View
5.25 in

Height

View
7.75 in

Depth

View
12 in

Weight

14 lb


Ordering Information 

Ordering Information

7218A - 16-Ch Voltage Data Acquisition
7214A - 16-Ch Strain/Bridge Data Acquisition

7218A - 16-Ch Voltage Data Acquisition

7220A - 16-Ch Transducer Data Acquisition