Products > Integrated Conditioning Acquisition & Control Systems > Integrated Conditioning Acquisition & Control System I/O Modules > 6000 Series Analog I/O Modules  
 

6000 Series Analog I/O Modules

Series 6000 analog I/O modules condition, amplify, filter and digitize signals from virtually any transducer. All modules have conditioning & amplifier per channel and nearly all modules allow for setting bridge completion, shunt calibration, transducer power, gain, etc. individually per channel. Following the conditioning/amplifier stage, multi-pole Bessel or Butterworth analog filters are provided on each channel and can be set or bypassed individually by program control. A number of the modules include a high level analog output providing a conditioned/filtered output to a redundant, external A/D system. A 16-Bit Successive Approximation A/D follows the analog filter stage. Some modules use a single A/D with sample and hold while others have an A/D per channel. Sample rates are programmable per channel to easily accommodate mixing high and low speed measurements into a single data stream. Programmable hardware based warnings and alarms are included in the channel-by-channel architecture and are detected by digital output modules in the system, providing an ultra-low latency control capability directly from the data acquisition system.


Click on a Product to view details.

Model 6013

Model 6013 8-Channel Instrumentation Amplifier-Filter-Digitizer


Features

  • Voltage, thermocouple & DC-LVDT inputs
  • Optional thermocouple reference junction box
  • Gains 1 to 5,000 with 0.05% accuracy
  • Automatic zero & gain calibration
  • Four-pole, low-pass filter
  • Up to 10 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6013 input module has eight channels, each with programmable gain instrumentation amplifier, low pass filter and sample and hold. The high level outputs are multiplexed and digitized to 16 bits then output to the 6000 data bus. A ninth reference temperature channel conditions the output of the temperature sensor in the ...

Model 6014

Model 6014 8-Channel Accelerometer Amplifier-Filter-Digitizer


Features

  • AC or DC coupled inputs, IEPE transducers
  • 2 to 20 mA current excitation
  • Gains 1 to 5,000 with 0.05% accuracy
  • Automatic zero & gain calibration
  • Four pole, low pass filter
  • Up to 10 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6014 input module has eight channels, each with AC or DC coupled programmable gain instrumentation amplifier, low pass filter and sample and hold. The high level outputs are multiplexed and digitized to 16 bits then output to the 6000 data bus. Each channel has a 2-20 mA current source for powering low impedance, voltage mode charge ...

Model 6017

Model 6017 32-Channel Voltage/Thermocouple Amplifier-Digitizer


Features

  • Voltage & thermocouple inputs
  • Optional thermocouple reference junction box
  • Gains 1 to 5,000 with 0.05% accuracy
  • Automatic zero & gain calibration
  • Low-pass filter
  • Up to 2 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6017 has thirty-two input channels organized in four eight-channel groups. The eight inputs in each group are multiplexed to a programmable gain differential amplifier and digitized with 16-bit resolution then output to the Series 6000 data bus. Each channel is capable of digitizing at up to 2,000 samples per second. The differential inputs ...

Model 6018

Model 6018 8-Channel RTD/Potentiometer Amplifier-Filter-Digitizer


Features

  • RTDs, potentiometers & other current excited transducers
  • Programmable current excitation
  • Gains 1 to 5,000 with 0.05% accuracy
  • Automatic zero & gain calibration
  • Four-pole, low-pass filter
  • Up to 10 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6018 input module has eight channels, each with programmable constant current excitation, programmable gain instrumentation amplifier, low pass filter and sample and hold. The high level outputs are multiplexed and digitized to 16 bits then output to the 6000 data bus.

The 6018 is used with RTDs, potentiometers ...

Model 6028

Model 6028 8-Channel Voltage Digitizer with Filter


Features

  • Differential input, ±10 Volts, ±50 Volts with optional attenuator
  • Buffered ±10 Volts analog outputs for redundancy
  • Four-pole filter, 100 Hz to 20 kHz
  • Up to 100 kS/s per channel with 16-bit digitizer
  • Two alarms with programmable upper and lower limits

Description

The 6028 input module has eight channels each with a differential input, unity gain instrumentation amplifier, low pass filter and 16-bit analog to digital converter. Each channel is capable of digitizing high-frequency signals at up to 100,000 samples per second. In addition each channel has a continuous, wideband analog output.

The 6028 is used to digitize ...

Model 6029

Model 6029 8-Channel AC/DC-Coupled/IEPE Amplifier-Filter-Digitizer


Features

  • AC or DC coupled inputs
  • 2 to 20 mA current excitation
  • Gains 1 to 5,000 with 0.05% accuracy
  • 4, 6 or 8-pole, low-pass filter
  • 100 kHz signal bandwidth
  • Up to 200 kS/s per channel with 16-bit resolution
  • Buffered ±10 Volt analog output

Description

The 6029 input module has eight channels each providing excitation for IEPE transducers, programmable AC or DC-coupled differential instrumentation amplifier, low-pass filter and analog to digital converter. Sample rate is programmable up to 200 kS/s with 16-bit resolution. Each channel has a buffered analog output that can be selected for wideband or filtered ...

Model 6030

Model 6030 2-Channel Strain/Bridge/IEPE Amplifier-Filter-Digitizer


Features

  • Dual inputs, strain/bridge or IEPE transducers
  • Programmable bridge configuration
  • Voltage & current excitation with remote sensing per channel
  • Automatic zero & balance
  • Voltage substitution and two or four step shunt calibration
  • Gains 1 to 5,000 up to 100 kHz bandwidth with 0.05% accuracy
  • Programmable low-pass filters
  • Up to 200kS/s per channel with 16-bit resolution
  • Dual buffered 10 Volt analog outputs

Description

Model 6030 is a two-channel, fully automated, high bandwidth, signal conditioning amplifier, filter and digitizer with dual inputs. The bridge input has voltage and current excitation, ...

Model 6031

Model 6031 2-Channel Transducer Amplifier-Filter-Digitizer


Features

  • Plug-in channel configuration & calibration card
  • Voltage & current excitation including remote sense
  • Gains 1 to 5,000 with 0.05% resolution
  • 50 kHz or 100 kHz bandwidth
  • Automatic zero & balance
  • Programmable low pass filters
  • Voltage substitution gain calibration
  • Digitized & analog outputs
  • Up to 250kS/s per channel with 16-bit resolution
  • Dual buffered 10 Volt analog outputs

Description

Model 6031 may not be regularly available. Please see Model 6030, 6060 or 6068 for similar applications.

The 6031 is a two-channel, fully programmable signal conditioning amplifier, filter and ...

Model 6032

Model 6032 4-Channel Strain/Bridge Transducer Amplifier-Filter-Digitizer


Features

  • Quarter, half & full bridge conditioning
  • Programmable excitation with remote sensing
  • Shunt & voltage calibration
  • Automatic zero & balance
  • Gains 1 to 5,000 with 0.05% accuracy
  • Fixed or programmable filter
  • Up to 20 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6032 input module has four channels of high performance signal-conditioning amplifier-digitizers for strain gages and bridge transducers. Each channel has programmable excitation with remote sensing, voltage calibration, local or remote shunt calibration, programmable gain instrumentation ...

Model 6033

Model 6033 8-Channel Strain/Bridge Transducer Amplifier-Filter-Digitizer


Features

  • Quarter, half & full bridge conditioning
  • Voltage excitation up to 12 Volts
  • Shunt & voltage calibration
  • Automatic zero & balance
  • Gains 1 to 5,000 with 0.05% accuracy
  • Four-pole low-pass filter
  • Up to 10 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

Model 6033 may not be regularly available. Please see Model 6035, 6038 or 6039 for similar applications.

The 6033 input module has eight channels of transducer signal conditioning and digitizer. Each channel has regulated voltage excitation, programmable gain instrumentation amplifier, four-pole ...

Model 6035

Model 6035 8-Channel Strain/Bridge Transducer Amplifier-Filter-Digitizer


Features

  • Programmable input configuration, 1/4, 1/2 & full bridge
  • Voltage excitation programmable / regulated for each channel
  • Shunt & voltage calibration
  • Automatic balance & zero
  • Gains 1 to 5,000 with 0.05% accuracy
  • Four-pole, low-pass filter
  • Up to 10 KS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6035 input module has eight channels of programmable transducer signal conditioning amplifiers and digitizer. Each channel has programmable voltage excitation, bridge completion and balance, programmable gain instrumentation amplifier, four-pole low pass ...

Model 6036

Model 6036 4-Channel Charge/IEPE Amplifier-Filter-Digitizer


Features

  • Dual inputs, charge & IEPE
  • 0.04 to 10,000 mV/pC charge gain
  • 2-20mA current source for IEPE transducers
  • 1 to 5,000 voltage gain with ±0.05% accuracy
  • 100 kHz bandwidth
  • Charge & voltage insertion calibration
  • Continuously programmable, 4-pole low-pass filter
  • Up to 200kS/s per channel with 16-bit resolution
  • Buffered 10 Volt analog outputs
  • Two alarms with programmable upper & lower limits

Description

Model 6036 is a four-channel, programmable charge amplifier, filter and digitizer with a second input for piezoelectric sensors with integrated electronics (IEPE).

The ...

Model 6037

Model 6037 8-Channel Strain/Bridge Transducer Amplifier-Filter-Digitizer


Features

  • Programmable input configuration, 1/4, 1/2 & full bridge
  • Automatic gain ranging
  • Strain gage simulation resistor
  • Excitation up to 12 Volts, regulated per channel
  • Automatic balance & zero
  • Voltage & bipolar shunt calibration
  • Four frequency programmable low-pass filter
  • Up to 10kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6037 has eight channels of strain gage or transducer signal conditioning amplifiers and digitizer. Each channel has programmable voltage excitation, programmable bridge completion and automatic balance, programmable ...

Model 6038

Model 6038 8-Channel Strain/Bridge Transducer Amplifier - Filter-Digitizer


Features

  • Programmable input configuration, 1/4, 1/2 & full bridge
  • Programmable excitation with remote sensing
  • Shunt & voltage calibration
  • Automatic zero & balance
  • Gains 1 to 5,000 with 0.05% accuracy
  • Four-pole, low-pass filter
  • Up to 10 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6038 input module has eight channels of programmable transducer signal conditioning amplifiers, filters and digitizer. Each channel has programmable voltage excitation, bridge completion and balance, programmable gain instrumentation amplifier and four-pole low pass filter. ...

Model 6039

Model 6039 8-Channel Strain/Bridge Transducer Amplifier - Filter-Digitizer


Features

  • Programmable input configuration, ¼, ½ & full bridge
  • Programmable voltage excitation with remote sensing
  • Additional ±12 or ±15 or 28 Volt transducer power
  • Two-step shunt & voltage substitution calibration
  • Gains 1 to 5,000 with 0.05% accuracy
  • Programmable 4, 6 or 8 pole low-pass filter
  • 6039B: Up to 10kS/s per channel with 16-bit resolution
  • 6039C: Up to 20ks/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6039 input module has eight channels of high performance signal-conditioning amplifier-digitizers for strain ...

Model 6052

Model 6052 4-Channel Strain/Bridge Transducer Amplifier - Filter-Digitizer


Features

  • Programmable input configuration ¼, ½ & full bridge
  • Programmable excitation with remote sensing
  • Shunt & voltage calibration
  • Automatic zero & balance
  • Gains 1 to 5,000 with 0.05% accuracy
  • Model 6052: Up to 20kS/s per channel with 16-bit resolution
  • Model 6052C: Up to 50kS/s per channel with 16-bit resolution
  • Buffered 10 Volt analog output
  • Two alarms with programmable upper & lower limits

Description

The 6052 input module has four channels of high performance signal-conditioning amplifier-digitizers for strain gages and bridge transducers. Each channel has ...

Model 6052

Model 6053 4-Channel Strain/Bridge Transducer Amplifier-Filter-Analog Outputs


--- Coming Soon ---

  • Isolated excitation & input with 300 Volts common mode
  • Programmable input configuration ¼, ½ & full bridge
  • Programmable excitation with remote sensing
  • Shunt & voltage calibration
  • Automatic zero & balance
  • Gains 1 to 5,000 with 0.05% accuracy
  • Up to 40 kS/s per channel with 16-bit resolution
  • Two buffered 10 Volt analog outputs per channel
  • Two alarms with programmable upper & lower limits

Description

The 6053 input module has four channels of high performance signal-conditioning amplifier-digitizers for strain gages and bridge transducers. Each channel has ...

Model 6060

Model 6060 2-Channel Transducer Amplifier-Filter-Digitizer, 300CMV


Features

  • Isolated excitation & input with 300 Volts common mode
  • Plug-in channel configuration & calibration card
  • Voltage & current excitation with remote sensing
  • Automatic zero & balance
  • Voltage substitution, DAC or 2/4 step shunt calibration
  • Gains 1 to 5,000 with 50 kHz or 100 kHz bandwidth
  • Four six-pole low-pass filters, optional programmable filter
  • Up to 200 kS/s per channel with 16-bit resolution
  • Dual buffered 10 Volt analog outputs

Description

The 6060 is a two-channel signal conditioning amplifier-digitizer module with 50 kHz or 100 kHz bandwidth and both digitized and analog outputs. The ...

Model 6060

Model 6060GV 2-Channel Transducer Amplifier-Filter-Digitizer, Galvanic 300CMV


Features

  • Galvanically isolated excitation & input with 300 Volts common mode
  • Plug-in channel configuration & calibration card
  • Voltage & current excitation with remote sensing
  • Automatic zero & balance
  • Voltage substitution, DAC or 2/4 step shunt calibration
  • Gains 1 to 5,000 with 50 kHz or 100 kHz bandwidth
  • Four six-pole low-pass filters, optional programmable filter
  • Up to 200 kS/s per channel with 16-bit resolution
  • Dual buffered 10 Volt analog outputs

Description

The 6060GV is a two-channel Galvanically isolated signal conditioning amplifier-digitizer module with 50 kHz or 100 kHz bandwidth and both ...

Model 6060

Model 6062 2-Channel Transducer Amplifier-Filter-Digitizer, 10CMV


Features

  • Plug-in channel configuration & calibration card
  • Voltage & current excitation with remote sensing
  • Automatic zero & balance
  • Voltage substitution, DAC or 2/4 step shunt calibration
  • Gains 1 to 5,000 with 50 kHz or 100 kHz bandwidth
  • Four six-pole low-pass filters, optional programmable filter
  • Up to 200 kS/s per channel with 16-bit resolution
  • Dual buffered 10 Volt analog outputs

Description

The 6062 is a two-channel signal conditioning amplifier digitizer module with 50 kHz or 100 kHz bandwidth and both digitized and analog outputs. The bridge input is ten-wire shielded with programmable constant voltage or ...

Model 6060

Model 6065 2-Channel Instrumentation Amplifier-Filter-Digitizer, 300CMV


Features

  • Isolated input with 300 Volts common mode
  • Automatic zero
  • Voltage Substitution Calibration
  • Gains 1 to 5,000 with 50 kHz or 100 kHz bandwidth
  • Programmable low-pass filters
  • Up to 200kS/s per channel with 16-bit resolution
  • Dual buffered 10 Volt analog outputs

Description

The 6065 is a two-channel instrumentation amplifier-digitizer module. Each channel has isolated input, 100 kHz bandwidth and two outputs that can be filtered or wideband.

The input is two-wire shielded and is isolated from the outputs, power and control interface. This gives the user complete freedom to ground the input without creating ground loops that ...

Model 6068

Model 6068 2-Channel Transducer Amplifier-Filter-Digitizer, 300CMV


Features

  • Plug-in module configures channel for multiple transducer types & calibration modes
  • Voltage & current excitation with remote sensing
  • Isolated excitation & input with 300 Volts common mode
  • Voltage & shunt calibration
  • Gains 1 to 5,000 with 100 kHz bandwidth
  • Up to 200 kS/s per channel with 16-bit resolution
  • Continuously programmable 6-pole low pass filter
  • Dual buffered 10 Volt analog outputs

Description

The 6068 is a two-channel signal conditioning amplifier-digitizer module featuring 100 kHz bandwidth and both digitized and analog outputs. The base board contains both constant voltage with remote ...

© 2022, Pacific Instruments, Inc. Catalog IndexPrivacy PolicySite Map