Series 6000 analog I/O modules condition, amplify, filter and digitize signals from virtually any transducer. All modules have conditioning & amplifier per channel and nearly all modules allow for setting bridge completion, shunt calibration, transducer power, gain, etc. individually per channel. Following the conditioning/amplifier stage, multi-pole Bessel or Butterworth analog filters are provided on each channel and can be set or bypassed individually by program control. A number of the modules include a high level analog output providing a conditioned/filtered output to a redundant, external A/D system. A 16-Bit Successive Approximation A/D follows the analog filter stage. Some modules use a single A/D with sample and hold while others have an A/D per channel. Sample rates are programmable per channel to easily accommodate mixing high and low speed measurements into a single data stream. Programmable hardware based warnings and alarms are included in the channel-by-channel architecture and are detected by digital output modules in the system, providing an ultra-low latency control capability directly from the data acquisition system.
The 6013 input module has eight channels, each with programmable gain instrumentation amplifier, low pass filter and sample and hold. The high level outputs are multiplexed and digitized to 16 bits then output to the 6000 data bus. A ninth reference temperature channel conditions the output of the temperature sensor in the ...
The 6014 input module has eight channels, each with AC or DC coupled programmable gain instrumentation amplifier, low pass filter and sample and hold. The high level outputs are multiplexed and digitized to 16 bits then output to the 6000 data bus. Each channel has a 2-20 mA current source for powering low impedance, voltage mode charge ...
The 6017 has thirty-two input channels organized in four eight-channel groups. The eight inputs in each group are multiplexed to a programmable gain differential amplifier and digitized with 16-bit resolution then output to the Series 6000 data bus. Each channel is capable of digitizing at up to 2,000 samples per second. The differential inputs ...
RTDs, potentiometers & other current excited transducers
Programmable current excitation
Gains 1 to 5,000 with 0.05% accuracy
Automatic zero & gain calibration
Four-pole, low-pass filter
Up to 10 kS/s per channel with 16-bit resolution
Two alarms with programmable upper & lower limits
Description
The 6018 input module has eight channels, each with programmable constant current excitation, programmable gain instrumentation amplifier, low pass filter and sample and hold. The high level outputs are multiplexed and digitized to 16 bits then output to the 6000 data bus.
Differential input, ±10 Volts, ±50 Volts with optional attenuator
Buffered ±10 Volts analog outputs for redundancy
Four-pole filter, 100 Hz to 20 kHz
Up to 100 kS/s per channel with 16-bit digitizer
Two alarms with programmable upper and lower limits
Description
The 6028 input module has eight channels each with a differential input, unity gain instrumentation amplifier, low pass filter and 16-bit analog to digital converter. Each channel is capable of digitizing high-frequency signals at up to 100,000 samples per second. In addition each channel has a continuous, wideband analog output.
The 6029 input module has eight channels each providing excitation for IEPE transducers, programmable AC or DC-coupled differential instrumentation amplifier, low-pass filter and analog to digital converter. Sample rate is programmable up to 200 kS/s with 16-bit resolution. Each channel has a buffered analog output that can be selected for wideband or filtered ...
Voltage & current excitation with remote sensing per channel
Automatic zero & balance
Voltage substitution and two or four step shunt calibration
Gains 1 to 5,000 up to 100 kHz bandwidth with 0.05% accuracy
Programmable low-pass filters
Up to 200kS/s per channel with 16-bit resolution
Dual buffered 10 Volt analog outputs
Description
Model 6030 is a two-channel, fully automated, high bandwidth, signal conditioning amplifier, filter and digitizer with dual inputs. The bridge input has voltage and current excitation, ...
The 6032 input module has four channels of high performance signal-conditioning amplifier-digitizers for strain gages and bridge transducers. Each channel has programmable excitation with remote sensing, voltage calibration, local or remote shunt calibration, programmable gain instrumentation ...
Model 6033 may not be regularly available. Please see Model 6035, 6038 or 6039 for similar applications.
The 6033 input module has eight channels of transducer signal conditioning and digitizer. Each channel has regulated voltage excitation, programmable gain instrumentation amplifier, four-pole ...
Programmable input configuration, 1/4, 1/2 & full bridge
Voltage excitation programmable / regulated for each channel
Shunt & voltage calibration
Automatic balance & zero
Gains 1 to 5,000 with 0.05% accuracy
Four-pole, low-pass filter
Up to 10 KS/s per channel with 16-bit resolution
Two alarms with programmable upper & lower limits
Description
The 6035 input module has eight channels of programmable transducer signal conditioning amplifiers and digitizer. Each channel has programmable voltage excitation, bridge completion and balance, programmable gain instrumentation amplifier, four-pole low pass ...
Model 6036 is a four-channel, programmable charge amplifier, filter and digitizer with a second input for piezoelectric sensors with integrated electronics (IEPE).
Programmable input configuration, 1/4, 1/2 & full bridge
Automatic gain ranging
Strain gage simulation resistor
Excitation up to 12 Volts, regulated per channel
Automatic balance & zero
Voltage & bipolar shunt calibration
Four frequency programmable low-pass filter
Up to 10kS/s per channel with 16-bit resolution
Two alarms with programmable upper & lower limits
Description
The 6037 has eight channels of strain gage or transducer signal conditioning amplifiers and digitizer. Each channel has programmable voltage excitation, programmable bridge completion and automatic balance, programmable ...
Programmable input configuration, 1/4, 1/2 & full bridge
Programmable excitation with remote sensing
Shunt & voltage calibration
Automatic zero & balance
Gains 1 to 5,000 with 0.05% accuracy
Four-pole, low-pass filter
Up to 10 kS/s per channel with 16-bit resolution
Two alarms with programmable upper & lower limits
Description
The 6038 input module has eight channels of programmable transducer signal conditioning amplifiers, filters and digitizer. Each channel has programmable voltage excitation, bridge completion and balance, programmable gain instrumentation amplifier and four-pole low pass filter. ...
Programmable input configuration ¼, ½ & full bridge
Programmable excitation with remote sensing
Shunt & voltage calibration
Automatic zero & balance
Gains 1 to 5,000 with 0.05% accuracy
Model 6052: Up to 20kS/s per channel with 16-bit resolution
Model 6052C: Up to 50kS/s per channel with 16-bit resolution
Buffered 10 Volt analog output
Two alarms with programmable upper & lower limits
Description
The 6052 input module has four channels of high performance signal-conditioning amplifier-digitizers for strain gages and bridge transducers. Each channel has ...
Isolated excitation & input with 300 Volts common mode
Plug-in channel configuration & calibration card
Voltage & current excitation with remote sensing
Automatic zero & balance
Voltage substitution, DAC or 2/4 step shunt calibration
Gains 1 to 5,000 with 50 kHz or 100 kHz bandwidth
Four six-pole low-pass filters, optional programmable filter
Up to 200 kS/s per channel with 16-bit resolution
Dual buffered 10 Volt analog outputs
Description
The 6060 is a two-channel signal conditioning amplifier-digitizer module with 50 kHz or 100 kHz bandwidth and both digitized and analog outputs. The ...
Voltage substitution, DAC or 2/4 step shunt calibration
Gains 1 to 5,000 with 50 kHz or 100 kHz bandwidth
Four six-pole low-pass filters, optional programmable filter
Up to 200 kS/s per channel with 16-bit resolution
Dual buffered 10 Volt analog outputs
Description
The 6062 is a two-channel signal conditioning amplifier digitizer module with 50 kHz or 100 kHz bandwidth and both digitized and analog outputs. The bridge input is ten-wire shielded with programmable constant voltage or ...
The 6065 is a two-channel instrumentation amplifier-digitizer module. Each channel has isolated input, 100 kHz bandwidth and two outputs that can be filtered or wideband.
The input is two-wire shielded and is isolated from the outputs, power and control interface. This gives the user complete freedom to ground the input without creating ground loops that ...
Isolated excitation & input with 300 Volts common mode
Voltage & shunt calibration
Gains 1 to 5,000 with 100 kHz bandwidth
Up to 200 kS/s per channel with 16-bit resolution
Continuously programmable 6-pole low pass filter
Dual buffered 10 Volt analog outputs
Description
The 6068 is a two-channel signal conditioning amplifier-digitizer module featuring 100 kHz bandwidth and both digitized and analog outputs. The base board contains both constant voltage with remote ...