Products > Signal Conditioning Systems > Series 6100 Automated Amplifiers > Signal Conditioning I/O Modules  
 

Signal Conditioning I/O Modules

I/O modules configure the 6100 to your specific needs. Pacific offers a broad selection of modules providing a high degree of flexibility, accuracy and performance. Series 6100 I/O Modules condition, amplify, filter and output high level signals to external data acquisition systems. Modules are selected according to functional and performance requirements for your application.


Click on a Product to view details.

Model 6030

Model 6120, 2-Channel Strain/Bridge/IEPE Amplifier-Filter-Analog Output


Features

  • Dual inputs, strain/bridge or IEPE transducers
  • Programmable bridge configuration
  • Voltage & current excitation with remote sensing per channel
  • Automatic zero & balance
  • Voltage substitution and two or four step shunt calibration
  • Gains 1 to 5,000 up to 100 kHz bandwidth with 0.05% accuracy
  • Programmable low-pass filters
  • Dual buffered 10 Volt analog outputs

Description

Model 6120 is a two-channel, fully automated, high bandwidth, signal conditioning amplifier and filter with dual inputs. The bridge input has voltage and current excitation, automatic balance, shunt calibration and programmable configuration for ...

Model 6029

Model 6129, 8-Channel AC/DC-Coupled/IEPE Amplifier-Filter-Analog Output


Features

  • AC or DC coupled inputs
  • 2 to 20 mA current excitation
  • Gains 1 to 5,000 with 0.05% accuracy
  • 4, 6 or 8-pole, low-pass filter
  • 100 kHz signal bandwidth
  • Buffered ±10 Volt analog output

Description

The 6129 input module has eight channels each providing excitation for IEPE transducers, programmable AC or DC-coupled differential instrumentation amplifier and low-pass filter. Each channel has a buffered analog output that can be selected for wideband or filtered response.

Using amplifier-per-channel architecture offers the highest accuracy and completely eliminates crosstalk between channels. It may be used to condition signals ...

Model 6031

Model 6131, 2-Channel Transducer Amplifier-Filter-Analog Output


Features

  • Plug-in channel configuration & calibration card
  • Voltage & current excitation including remote sense
  • Gains 1 to 5,000 with 0.05% resolution
  • 50 kHz or 100 kHz bandwidth
  • Automatic zero & balance
  • Programmable low pass filters
  • Voltage substitution gain calibration
  • Dual buffered 10 Volt analog outputs

Description

The 6131 is a two-channel, fully programmable signal conditioning amplifier and filter. It features a plug-on signal conditioning completion card that is available for strain gage, bridge, RTD, potentiometer, voltage-mode charge, voltage and current transducers. Each channel has a programmable gain ...

Model 6036

Model 6136, 4-Channel Charge/IEPE Amplifier-Filter-Analog Output


Features

  • Dual inputs, charge & IEPE
  • 0.04 to 10,000 mV/pC charge gain
  • 2-20mA current source for IEPE transducers
  • 1 to 5,000 voltage gain with ±0.05% accuracy
  • 100 kHz bandwidth
  • Charge & voltage insertion calibration
  • Continuously programmable, 4-pole low-pass filter
  • Buffered 10 Volt analog outputs

Description

Model 6136 is a four-channel, programmable charge amplifier, filter, analog output module with a second input for piezoelectric sensors with integrated electronics (IEPE).

The high-performance charge amplifier can be used to measure dynamic acceleration, pressure, force and strain from piezoelectric ...

Model 6052

Model 6152, 4-Channel Strain/Bridge Transducer Amplifier-Filter-Analog Output


Features

  • Programmable input configuration 1/4, 1/2 & full bridge
  • Programmable excitation with remote sensing
  • Shunt & voltage calibration
  • Automatic zero & balance
  • Gains 1 to 5,000 with 0.05% accuracy
  • Buffered 10 Volt analog output

Description

The 6152 input module has four channels of high performance signal-conditioning amplifiers for strain gages and bridge transducers. Each channel has programmable excitation with remote sensing, voltage calibration, local or remote shunt calibration, programmable gain instrumentation amplifier and four-pole low pass filter. Each channel provides a buffered analog output.

The 6152 is used ...

Model 6060

Model 6160 2-Channel Transducer Amplifier-Filter-Analog Output, 300CMV


Features

  • Isolated excitation & input with 300 Volts common mode
  • Plug-in channel configuration & calibration card
  • Voltage & current excitation with remote sensing
  • Automatic zero & balance
  • Voltage substitution, DAC or 2/4 step shunt calibration
  • Gains 1 to 5,000 with 50 kHz or 100 kHz bandwidth
  • Four six-pole low-pass filters, optional programmable filter
  • Dual buffered 10 Volt analog outputs

Description

The 6160 is a two-channel signal conditioning amplifier module with 50 kHz or 100 kHz bandwidth and analog outputs. The bridge input is ten-wire shielded with programmable constant voltage or constant current ...

Model 6060

Model 6165, 2-Channel Instrumentation Amplifier-Filter-Analog Output, 300CMV


Features

  • Isolated input with 300 Volts common mode
  • Automatic zero
  • Voltage Substitution Calibration
  • Gains 1 to 5,000 with 50 kHz or 100 kHz bandwidth
  • Programmable low-pass filters
  • Dual buffered 10 Volt analog outputs

Description

The 6165 is a two-channel instrumentation amplifier module. Each channel has isolated input, 100 kHz bandwidth and two outputs that can be filtered or wideband.

The input is two-wire shielded and is isolated from the outputs, power and control interface. This gives the user complete freedom to ground the input without creating ground loops that introduce noise and offset errors. The isolation provides for ...

Model 6068

Model 6168, 2-Channel Transducer Amplifier-Filter-Analog Output, 300CMV


Features

  • Plug-in module configures channel for multiple transducer types & calibration modes
  • Voltage & current excitation with remote sensing
  • Isolated excitation & input with 300 Volts common mode
  • Voltage & shunt calibration
  • Gains 1 to 5,000 with 100 kHz bandwidth
  • Continuously programmable 6-pole low pass filter
  • Dual buffered 10 Volt analog outputs

Description

The 6168 is a two-channel signal conditioning amplifier module featuring 100 kHz bandwidth and analog outputs. The base board contains both constant voltage with remote sensing and constant current programmable excitation supplies, high-bandwidth instrumentation ...

© 2024, Pacific Instruments, Inc. Catalog IndexPrivacy PolicySite Map